Description

After completing a build using Live Coding, a horizontal scroll bar appears at the bottom of the Live Coding Console window since some of the lines of text are longer than the window can display. The scroll bar does not respond to attempts to interact with it in order to read more of some of the lines of text in the window.

REGRESSION:
No. This is a new feature in 4.22.

Steps to Reproduce
  1. Create a new code project.
  2. Open the project in both Visual Studio and the Editor.
  3. Enable Live Coding for the project in the Editor.
  4. Add a comment to any of the project's .cpp files.
  5. Save the file in Visual Studio.
  6. Use Ctrl-Alt-F11 to start a Live Coding update.
  7. When the build completes, drag the scroll bar at the bottom of the Live coding Console window.

RESULT:
The scroll bar cannot be interacted with.

EXPECTED:
The scroll bar can be interacted with.

Have Comments or More Details?

There's no existing public thread on this issue, so head over to Questions & Answers just mention UE-73027 in the post.

0
Login to Vote

Fixed
ComponentUE - Foundation - Cpp Tools - Live Coding
Affects Versions4.224.23
Target Fix4.22.1
Fix Commit6018519
Main Commit6018719
CreatedApr 18, 2019
ResolvedApr 19, 2019
UpdatedMay 13, 2019
View Jira Issue